Motorized High-Load Vertical Translation Stage


  • Motorized Stage with 50 mm (1.97") Vertical Travel
  • High Load Capacity of 20 kg (44 lbs)
  • Integrated Controller Facilitates Local or Remote Control

MLJ150

50 mm (1.97") Vertical Translation Stage with Integrated Controller

Power Supply, USB, and RS232 Ports

Manual Control Keypad

Related Items


Please Wait
Key Specificationsa
Travel 50 mm (1.97")
Load (Max) 20 kg (44 lbs)
Velocity (Max) 3.0 mm/s (All Loads)
Pitch/Roll Error <500 µRad
Unidirectional Repeatability <10 µm
Deck Parallelism <150 µm Over Full Range of Travel
  • Please see the Specs tab for a complete list of specifications.
MLJ150 Mounted onto an Optical Table
Click to Enlarge
The Fully Extended MLJ150(/M) Mounted onto a Nexus Optical Table by 1/4"-20 (M6) Cap Screws

Features

  • Motorized High-Load Vertical Translation Stage with Local or Remote Control
  • USB and RS232 Computer Connections
  • Smooth, Stepper Motor Driven Linear Motion
  • Full Kinesis® or APT™ Software Control Suite (See Motion Control Software Tab for Details)
  • Large Mounting Platform with 1/4"-20 (M6) Taps
  • Location-Specific Power Supply Included

The MLJ150(/M) Motorized Vertical Translation Stage offers up to 50 mm of smooth, stepper motor driven linear height adjustment. Its integrated electronic controller allows for local control or CPU control via our software. This stage provides a rugged, height-adjustable platform ideal for mounting optomechanical sub-assemblies requiring height adjustment. It incorporates a large 5.83" x 5.16" mounting platform that is capable of moving loads up to 20 kg at up to 3 mm/s. Guards are fitted to completely eliminate finger traps and other obstructions. These features make it ideal to use as a heavy-duty lab jack.

The integrated electronic contoller facilitates local control via the keypad buttons and velocity potentiometer, as seen in the drawing to the right, as well as above. Alternatively, the MLJ150(/M) can be controlled remotely via USB or RS232 connections (see the Pin Diagram tab for connector information) by utilizing our Kinesis® or APT™ software suites. Parameter settings can be adjusted on the PC and stored in non-volatile memory within the unit itself. When the unit is next powered up, these settings are applied automatically. This feature is particularly useful when operating the unit manually in the absence of a PC link. Furthermore, the magnetic limit switches can be configured using flexible logic settings.

The stage offers excellent rigidity and platform parallelism. The top plate has twenty-five 1/4"-20 (M6) tapped holes with 0.31" (8.0 mm) depth, while the bottom plate has clearance slots that can be used to mount the stage to an optical breadboard, as shown to the right. The unit is supplied with a location-specific power supply with an input of 100 to 240 VAC. Please connect the power supply unit (PSU) to the stage before connecting the PSU to a power outlet. A USB cable for connection to a PC is also included.

Calibration Files
Each MLJ150(/M) stage is calibrated at the factory. Calibration enables the controller to correct for any mechanical errors present in the system. Mechanical components, such as the lead screw and linkages, can be machined only within a certain tolerance. These mechanical errors result in deviations of the actual position from the commanded position. However, the deviations are repeatable and can be compensated for using the Kinesis or APT software and included calibration files. These files are used by the Kinesis or APT software to convert the position entered by the user into the required mechanical motion. The calibration files can be downloaded by clicking on the red Docs icon () next to the item # below and entering your device's serial number under "Download Calibration Data."

Software Control
USB and RS232 connectivity provides simple PC-controlled operation with two available software platforms: our new Kinesis software package, or our legacy APT software package. The Kinesis Software features new .NET controls which can be used by 3rd party developers working in the latest C#, Visual Basic, LabView or any .NET compatible languages to create custom applications. Our legacy APT software allows the user to quickly set up complex move sequences with advanced controls made possible via the ActiveX® programming environment. For example, all relevant operating parameters are set automatically by the software for Thorlabs stage and actuator products. For more details on both software packages, please see the Motion Control Software, Kinesis Tutorials, and APT Tutorials tabs for more details.

Click for Details
The 5.83" x 5.16" (148 mm x 131 mm) top platform of the MLJ150(/M) has twenty-five 1/4"-20 (M6) mounting taps. The control keypad for manual control can be seen here.
Item # MLJ150 MLJ150/M
Stage Specifications
Travel 50 mm (1.97")
Mounting Taps 1/4"-20, 0.31" deep M6, 8.0 mm deep
Gear Ratio 3 to 1 (1 228 800 microsteps = 1 mm Travel)
Load (Max) 44 lbs  20 kg
Moment Load (Max) 5 N•m (44 in-lb)
Velocity (Max) 3.0 mm/s at All Loads
Resolution (Theoretical) 0.8 nm
Deck Parallelism <150 µm Over Full Range of Travel
Unidirectional Repeatability (Software Corrected) <10 µm
Bidirectional Repeatability (System Backlash) <50 µm
Pitch/Roll Error over 2" (50 mm) Travel <500 µRad
Accuracy <30 µm
Lead Screw Pitch 1.0 mm
Controller Specifications
Microsteps per Full Step 2048
Microsteps per Revolution of Motor 409 600
Motor Drive Voltage 24 V
Motor Drive Power Up to 25 W (Peak) / 12.5 W (Avg)
Motor Speeds Up to 720 RPM
Motor Specifications
Step Angle 1.8° (50 Poles and ±2 Phases for 360° Divided by 200, or 1.8°)
Step Accuracy 5%
Rated Phase Current 0.85 A
Phase Resistance 5.4 Ω
Phase Inductance 5.6 mH
Holding Torque 20 N•cm
Detent Torque 2.0 N•cm
Operating Temperature -20 to 40 °C (Motor Specification Only)
Input Power Requirements
Current 1.25 A
Voltage 24 VDC
Power 30 W (Peak)
General
Dimensions (W x D x H) Extended 5.16" x 8.53" x 4.53" 131.0 mm x 216.7 mm x 115 mm
Retracted 5.16" x 8.53" x 2.56" 131.0 mm x 216.7 mm x 65.0 mm
Weight  5.4 lbs 2.47 kg
Pin Description
1 Not Connected
2 TX (Controller Input)
3 RX (Controller Output)
4 Not Connected
5 Ground
6 Not Connected
7 Clear to Send (CTS) Input
8 Request to Send (RTS) Output
9 Not Connected

Computer Connections

USB Type B

USB Type B

USB Type B to Type A Cable Included

RS232

Thorlabs offers two platforms to drive our wide range of motion controllers: our Kinesis® software package or the legacy APT™ (Advanced Positioning Technology) software package. Either package can be used to control devices in the Kinesis family, which covers a wide range of motion controllers ranging from small, low-powered, single-channel drivers (such as the K-Cubes™ and T-Cubes™) to high-power, multi-channel, modular 19" rack nanopositioning systems (the APT Rack System).

The Kinesis Software features .NET controls which can be used by 3rd party developers working in the latest C#, Visual Basic, LabVIEW™, or any .NET compatible languages to create custom applications. Low-level DLL libraries are included for applications not expected to use the .NET framework. A Central Sequence Manager supports integration and synchronization of all Thorlabs motion control hardware.

Kinesis Software
Kinesis GUI Screen
APT Software
APT GUI Screen

Our legacy APT System Software platform offers ActiveX-based controls which can be used by 3rd party developers working on C#, Visual Basic, LabVIEW™, or any Active-X compatible languages to create custom applications and includes a simulator mode to assist in developing custom applications without requiring hardware.

By providing these common software platforms, Thorlabs has ensured that users can easily mix and match any of the Kinesis and APT controllers in a single application, while only having to learn a single set of software tools. In this way, it is perfectly feasible to combine any of the controllers from single-axis to multi-axis systems and control all from a single, PC-based unified software interface.

The software packages allow two methods of usage: graphical user interface (GUI) utilities for direct interaction with and control of the controllers 'out of the box', and a set of programming interfaces that allow custom-integrated positioning and alignment solutions to be easily programmed in the development language of choice.

A range of video tutorials is available to help explain our APT system software. These tutorials provide an overview of the software and the APT Config utility. Additionally, a tutorial video is available to explain how to select simulator mode within the software, which allows the user to experiment with the software without a controller connected. Please select the APT Tutorials tab above to view these videos.

Software

Kinesis Version 1.14.25

The Kinesis Software Package, which includes a GUI for control of Thorlabs' Kinesis and APT™ system controllers.

Also Available:

  • Communications Protocol
Software Download

Software

APT Version 3.21.4

The APT Software Package, which includes a GUI for control of Thorlabs' APT™ and Kinesis system controllers.

Also Available:

  • Communications Protocol
Software Download

Thorlabs' Kinesis® software features new .NET controls which can be used by third-party developers working in the latest C#, Visual Basic, LabVIEW™, or any .NET compatible languages to create custom applications.

C#
This programming language is designed to allow multiple programming paradigms, or languages, to be used, thus allowing for complex problems to be solved in an easy or efficient manner. It encompasses typing, imperative, declarative, functional, generic, object-oriented, and component-oriented programming. By providing functionality with this common software platform, Thorlabs has ensured that users can easily mix and match any of the Kinesis controllers in a single application, while only having to learn a single set of software tools. In this way, it is perfectly feasible to combine any of the controllers from the low-powered, single-axis to the high-powered, multi-axis systems and control all from a single, PC-based unified software interface.

The Kinesis System Software allows two methods of usage: graphical user interface (GUI) utilities for direct interaction and control of the controllers 'out of the box', and a set of programming interfaces that allow custom-integrated positioning and alignment solutions to be easily programmed in the development language of choice.

For a collection of example projects that can be compiled and run to demonstrate the different ways in which developers can build on the Kinesis motion control libraries, click on the links below. Please note that a separate integrated development environment (IDE) (e.g., Microsoft Visual Studio) will be required to execute the Quick Start examples. The C# example projects can be executed using the included .NET controls in the Kinesis software package (see the Kinesis Software tab for details).

C Sharp Icon Click Here for the Kinesis with C# Quick Start Guide
Click Here for C# Example Projects
Click Here for Quick Start Device Control Examples
C Sharp Icon

LabVIEW
LabVIEW can be used to communicate with any Kinesis- or APT-based controller via .NET controls. In LabVIEW, you build a user interface, known as a front panel, with a set of tools and objects and then add code using graphical representations of functions to control the front panel objects. The LabVIEW tutorial, provided below, provides some information on using the .NET controls to create control GUIs for Kinesis- and APT-driven devices within LabVIEW. It includes an overview with basic information about using controllers in LabVIEW and explains the setup procedure that needs to be completed before using a LabVIEW GUI to operate a device.

Labview Icon Click Here to View the LabVIEW Guide
Click Here to View the Kinesis with LabVIEW Overview Page
Labview Icon

These videos illustrate some of the basics of using the APT System Software from both a non-programming and a programming point of view. There are videos that illustrate usage of the supplied APT utilities that allow immediate control of the APT controllers out of the box. There are also a number of videos that explain the basics of programming custom software applications using Visual Basic, LabView and Visual C++. Watch the videos now to see what we mean.

  Click here to view the video tutorial  

To further assist programmers, a guide to programming the APT software in LabView is also available.

Labview Icon Click here to view the LabView guide Labview Icon

Posted Comments:
user  (posted 2020-04-22 23:02:27.23)
Hello, I have a question regarding the gearbox ratio of the MLJ050/M labjack. The specifications on the catalogue page say the gearbox ratio is 3 to 1. Additionally, the default settings XML file for Kinesis specifies a gearbox ratio of 3 to 1. However, the Thorlabs APT Communication Protocol document says the gearing is 1 mm/turn (i.e. ratio of 1 to 1). Can you please advise which is correct? Thank you!
DJayasuriya  (posted 2020-04-24 06:50:20.0)
Response from Dinuka at Thorlabs: Thanks for your query. Yes the gear box ratio is 3:1, from the APT protocol document, 1mm/turn is not the gear ratio relates to the encoder. The trinamics encoder gives 409600 micro‐steps per revolution. i.e. a 1 mm move requires 1228800 microsteps = 409600 microsteps * 3. Hope this helps.
Salman Naqvi  (posted 2019-10-24 20:34:32.427)
Hi, We have half a dozen of these labjacks in our lab which speaks of their utility for our task. Sadly, we have started to experience issues driving them to the desired position. Randomly during some motion, labjack would make a loud beep and instead of throwing any error, stop midway but report that it has reached the destination! This makes the stage extremely unreliable for repeatable measurements. I haven't been able to find a way to troubleshoot it. For reference, we have been sending commands 0x0480 and 0x0453 via serial port on Windows 8. Can you please reach back to me and help us fix the problem if a fix exists? Thanks - Salman Naqvi Hardware Engineering, Apple Inc Cupertino, CA
cwright  (posted 2019-10-28 04:13:42.0)
Hello Salman, I'm sorry to hear you are having these issues but I am sure we can help resolve this. I will reach out to you directly about this.
user  (posted 2019-08-13 10:28:06.373)
Does the stage need to be re-calibrated after extensive use? (0-40mm travel distance, 20 times/ day)
AManickavasagam  (posted 2019-08-14 09:07:12.0)
Response from Arunthathi at Thorlabs: Thanks for your query. This will also depend on how long you have used the stage for, the load on it and etc. Typically we do not have a calibration schedule for this stage. FYI you can download the calibration file from the website or alternatively please contact your local tech support office with the serial number of your stage and we will be able to provide the calibration file.
user  (posted 2019-07-19 15:25:46.223)
When I connected this product with Kineses,the PC can not get response from the labjack,and the diagnostic log of kineses showed "Device not reponding(Error Code-33)".I don't know why this happened.Can you please help me to find the problem and solution,thank you.
AManickavasagam  (posted 2019-07-26 03:46:33.0)
Response from Arunthathi at Thorlabs: Thanks for reaching out to us. ‘Error code 33’ (indicating a comms failure) usually appears when using old versions of Kinesis with new hardware (firmware). This is displayed as a Generic Error in .NET API help file. This usually resolves when using the latest software; updating the firmware, power cycling the device and also restarting your computer for the update to fully take effect. If you still have any issues please contact your local tech support office for further help.
Yanhua Ma  (posted 2019-07-03 10:37:08.87)
Hello, I am trying to control labjack MLJ150/M using the latest version of kinesis. When attempting to load the jack (connected by USB), kinesis fails with error "Device not responding (Error Code- 33)". How do I solve this problem?
AManickavasagam  (posted 2019-07-03 09:21:44.0)
Response from Arunthathi at Thorlabs: Thanks for contacting us. I have reached out to you directly to troubleshoot the issue you have.
Sang Min Lee  (posted 2019-04-23 08:50:08.047)
At first, the device was operating normally. It is currently recognized but does not work properly in kinesis. Attach the following log file contents. What is the problem and how can it be solved? 2019-04-23 17:40:18.082 Diagnostic $100013 Opening Device Collection 2019-04-23 17:40:18.082 Diagnostic $100014 Create Device: Thorlabs.MotionControl.DeviceManagerCLI.DeviceChannels 2019-04-23 17:40:18.082 Info $301100 Loaded Device Settings SettingsName = MLJ150/M Labjack DeviceAlias = CollateLogging = False OutputDebugMask = StdOutput OutputLogMask = StdLogging LoadSettingsOption = UseFileSettings 2019-04-23 17:40:18.082 Info $301112 Storing Device Configurations Device = 49954940 2019-04-23 17:40:18.083 Diagnostic $1146 RegisterDeviceSettingsFactory 2019-04-23 17:40:18.083 Info $1100 Loaded Device Settings CollateLogging = 0 DeviceAlias = LoadSettingsOption = 2 MustUseDeviceUnits = 0 OutputDebugMask = 7 OutputLogMask = 31 SettingsName = MLJ150/M Labjack 2019-04-23 17:40:18.083 Info $1112 Storing Device Configurations Device = 49954940 2019-04-23 17:40:18.086 Diagnostic 49954940 Processing Message: Value = ::Homed 2019-04-23 17:40:18.086 Diagnostic 49954940 Changing State: Value = IdleState 2019-04-23 17:40:18.237 Diagnostic 49954940 LoadDevice Success Device = 49954940 Handle = 0F80FBF0 2019-04-23 17:40:22.615 Error 49954940 Device not responding Error Code = 33 2019-04-23 17:40:22.934 Diagnostic $100015 Opened Device Collection
rmiron  (posted 2019-04-24 11:08:50.0)
Response from Radu at Thorlabs: Error code 33 suggests an USB communications-related problem. I will contact you directly in order to assist you in troubleshooting your device.
Hanna Dierks  (posted 2019-04-11 04:57:13.3)
HI! I'm also interested in the long term position stability of the MLJ150/M. In your response to nitzan_chamiel (2019-02-28) you mentioned that you are currently running some tests on this. Are there any (preliminary) results yet? For my experiment I would need stability in the sub micrometer range over several days, with a load of about 6kg. Is there any (e.g mechanical) creep you know of? Thanks in advance!
rmiron  (posted 2019-04-11 06:56:07.0)
Response from Radu at Thorlabs: Hello, Hanna. The testing that we ran was not extensive enough to enable us to post a specification on the website. Furthermore, it was not run in an isothermal environment. With that being said, I expect that the stage will drift by more than 1 um over several days. I will contact you directly in order to share the results I shared with Nitzan.
nitzan_chamiel  (posted 2019-02-28 00:00:31.263)
Hello, In my application I plan to use the MLJ150 for coarse z adjustment, and an additional LPS710E (piezo Z stage) on top of it for fine z adjustment. What is the stability of the MLJ150 when not moving? Also, would I get higher stability with power off? Thanks you, Nitzan
rmiron  (posted 2019-02-28 05:01:24.0)
Response from Radu at Thorlabs: Hello Nitzan. At the moment, we do not have sufficient test data in order to specify the stability of this stage. With that being said, we ran two stability tests for it last week. I will contact you directly in order to share this data with you. We think that it will be more stable if powered off, but this might depend on the load place on it and again, we do not have sufficient data to be certain that this is the case.
lebouquj  (posted 2019-02-21 14:00:33.18)
We would like to control this device via the RS232 with a socket from a C program. We could not find the format and list of accepted commands in the existing documentation. Do you have it ? Thanks.
rmiron  (posted 2019-02-22 07:29:39.0)
Response from Radu at Thorlabs: The documentation of our serial commands protocol can be found here: https://www.thorlabs.com/Software/Motion%20Control/APT_Communications_Protocol.pdf All the public commands are listed in that document. The protocol uses uint8 (hexadecimal) bytes, an 115200/8-N-1 configuration and no terminating bytes.
3206302534  (posted 2018-12-19 18:48:33.95)
I do want to konw how many μsteps is 50mm divided to?
rmiron  (posted 2018-12-19 10:32:10.0)
Response from Radu at Thorlabs: In MLJ150, 1 mm corresponds to 409600 μsteps. Therefore, 50 mm correspond to 20480000 μsteps. I will suggest internally that our serial communications protocol's documentation gets updated such that it mentions this conversion ratio.
akuznetsov  (posted 2017-11-15 22:09:15.357)
Is this another windows ONLY product or does RS-232 port mean that it can actually be used on a Mac with USB to RS-232 adapter? There are a lot of Thorlabs products >$1000 that only have a USB interface and Kinesis/APT software which means I can't use them on my bench which requires a Mac to control the device under test and as a result requires Mac controllable hardware.
bwood  (posted 2017-11-17 05:02:24.0)
Response from Ben at Thorlabs: Thanks you for your question. The MLJ150 can be controlled completely through the RS232 connector, so it should be suitable for your application. I would like to note that while APT/Kinesis requires Windows, all devices controlled with this software can also be controlled through serial communications, as per the protocol we offer in the software section. Furthermore, most controllers and devices have auxiliary I/O options, as an alternative to USB control.
oavramio  (posted 2017-11-10 12:31:10.803)
I am currently trying to develop an experimental set up for precise compression experiments. Thus, I am looking for a very precise vertical translation stage.Although I am very interesting in the motorised labjack MLJ050 devise I still need to know some more things: Which is the actual minimum velocity that the devise can achieve. A theoretical resolution of 0.8 nm and an accuracy of 30 micrometers is reported in the specs of the devise. What does this actually mean? How precisely would I be able to control the motor in terms of 1) Velocity, 2)Position. Would I be able, for instance, to control the exact number of steps of the motor I need him to do?
bwood  (posted 2017-11-14 06:15:47.0)
Response from Ben at Thorlabs: The theoretical minimum velocity is that which can be commanded by our motion control software. However, at low velocities the motion of any 2-phase stepper motor will become unstable. As you reduce the velocity of the stage, the movement may seem to microscopically ‘stop-start’ depending on the application’s requirements. This is due to the time between motor phases increasing to produce this ultra-low velocity which consequently leads to the motor stalling if there are torque hotspots, where say the pitch of the leadscrew is not perfect. This will vary between each model as at this slow speed any irregularities in the stage are emphasised. This would also be heavily dependent upon the load employed. This means it is hard to define the lower limits of the velocity. The theoretical resolution is the distance traveled in one microstep, however for the reasons above, moving by a set number of microsteps is impossible. The <30 µm value is the achievable accuracy of the stage.
lorenzo.alligo  (posted 2017-02-24 08:31:47.267)
I have a motorized labjack MLJ050, and having an issue when I launch the APTuser application. It give me an error that say "failed to load application settings. nConfiguration System failed to inizialize." I'm using a 64-bit software on a 64-bit system
bhallewell  (posted 2017-02-27 06:43:30.0)
Response from Ben at Thorlabs: Thank you for posting this feedback. We believe that this is typically associated with a corrupt install. I will contact you directly to make sure this is working for you.
Ian.Lloyd1262  (posted 2017-02-07 10:19:01.573)
I have a motorized labjack MLJ050/M that I would like to control using LabVIEW. I have followed your great tutorials and have got it working using ActiveX. I can not get it working using .NET I keep getting the message No suitable devices found. I am able to connect with the device using your Kinesis program. What could I e doing wrong? Thanks Ian
bhallewell  (posted 2017-02-09 09:54:27.0)
Response from Ben at Thorlabs: I would firstly recommend testing the device in the Kinesis application first, to ensure the stage is communicating with your PC correctly. When using the .NET framework please make sure you have copied over all Kinesis .dlls into your project & select the Lab Jack .NET control. We have some steps outlined within the following guide. https://www.thorlabs.com/Software/Motion%20Control/KINESIS/Kinesis-Labview.pdf I'd further recommend ensuring that you have the correct version of Kinesis installed which matches your OS & version of LabVIEW.
jingfang.wan  (posted 2016-05-06 08:39:43.787)
I want to use the labjack on a moving device. Possible to provide a battery driven / wireless version?
bwood  (posted 2016-05-09 03:48:21.0)
Response from Ben at Thorlabs: Thank you for your feedback. Unfortunately, we do not currently offer a battery alternative to the mains power supply for the LabJack. However, we would be happy to discuss your application with you, to see what advice we an give here. If you wish to do so, I can be contacted at techsupport.uk@thorlabs.com.
giuseppe.moschetti  (posted 2016-02-16 13:03:48.463)
is Deck Parallelism a static error, i.e. can it be corrected? Is it equivalent to straightness of the axes? We are concern about losing our x and y positioning when moving the motor up and down. Thanks Giuseppe
bwood  (posted 2016-02-17 05:56:43.0)
Response from Ben at Thorlabs: Thank you for your feedback. The deck parallelism is a static parallelism measurement, so you should be able to correct for this. Please note, there will be a pitch/yaw error over the travel, which we specify over 2" (50mm) as <500 µRad
Silvernightwave  (posted 2014-01-15 17:43:51.26)
Thank you! I fixed it with the callback method and set everything bwait=false. Now everything works. But most important: Thanks for the hint, that there excists a help file with all the definitions. That i didnt know. I only knew the developer support area. so thanks a lot! best regards
Silvernightwave  (posted 2014-01-14 17:31:22.09)
Hello, i'm using Labview to control the Motor. Unfortunatly during homing or moving (which takes 5-6 seconds) my Labview software isn't responding. Do you have any idea how to fix it? (Even in a simple software, labview isn't responding at all, not only the frontpanel e.g., it's the hole software including change between front and block diagram e.g.). Second question about a "is busy" function: Is there a command i could use to check if the system is still moving or if it is finished? I only know about the callback option. What is the "bwait" option at the command "MoveAbsolute"? I could not find out what this option changes. best regards
msoulby  (posted 2014-01-15 06:50:06.0)
Response from Mike at Thorlabs: All of the move commands have a bWait Boolean property. When bWait is set to TRUE then the move method will return only after the move has completed, the program flow will be halted until the move has completed. If bWait is set to FALSE then the method will return as soon as the move has initiated, allowing the program flow to continue without waiting for the move to complete. In labview setting bWait to TRUE may cause the GUI or front panel to freeze up until the move has completed, which will explain the 5-6 second wait you are experiencing. It is more efficient programming practice to set bWait to 'False' and respond to the MoveComplete event. This event driven approach allows your application to service other tasks while the motors are moving and will prevent your front panel from freezing up during the move. An alternative to the MoveComplete event would be to poll the status of the motor, to do this you would need to use the motor method LLGetStatusBits, details of which can be found in the APT server help file under Programming Guide>> Motor Control>>Motor Control Methods
t.nguyen14  (posted 2013-03-03 23:14:31.637)
We bought a Thorlabs labjack L490MZ/M from you few years ago, and now we want to calibrate it. But I don't have a calibration file as it is requested by ATP config software for calibarion. Could you please help to give us a calibration file ? Here is serial number of our Labjack : 46821236 Thank you very much for your help. Tuan D Nguyen Research Assistant School of Chemical Engineering The University of Queensland Australia
tcohen  (posted 2013-03-06 14:52:00.0)
Response from Tim at Thorlabs to Tuan: Thank you for contacting us. We have calibration files dating back to 08/09/10. For older L490MZ/M we can take the unit in for recalibration. I will contact you to continue this discussion.
bdada  (posted 2012-03-16 11:53:00.0)
Response from Buki at Thorlabs to macross: I am sorry to hear about the problems you're experiencing when using the L490MZ. I have addressed your two questions below. 1. It could be that the limit switch has been damaged. We just tested one unit with all the different setting options and it stopped every time even when the switch was ignored. We would be happy to evaluate your stage to see if the switch is broken, but please first verify the default limit switch and homing settings first: Homing: Direction - Reverse Limit Switch - Reverse HW Zero Offset: 0.2 Velocity: 0.4 Hardware Limit Switches: Reverse - Switch Makes Forward - Switch Makes 2. If you are still able to discover your hardware in APT firmware, please try and reprogram it again. Open APT config and select the Server tab. In here you can try to increase the Enumeration dwell time (how long the APT server spends looking for and initialising devices). Default is 5000ms, try 10000ms and make sure only one usb device is connected. We have contacted you directly to provide additional assistance and arrange for the return and evaluation of your lab jack, if needed.
macross  (posted 2012-03-15 14:26:16.0)
Use L490MZ occur two problem. 1.when homing, a stage moves n reverse direction but motor can't stop finally. Because it was not get the reverse limit switch signal. I need your help quickly. 2.after I use APT firmware to flash firmware, I can't see the GUI interface in APT user.
bdada  (posted 2012-02-10 19:19:00.0)
Response from Buki at Thorlabs to johannes.strauss: Thank you for your feedback on our motorized lab jack. Due to the scissor action of the stage, you will see the worst 'twist' on the first move, so you will see the error no matter the step size or travel distance. We are currently redesigning this stage to improve the deck parallelism.
johannes.strauss  (posted 2012-02-08 02:53:20.0)
Deck parallelism (<250µm hole travel range) is pretty much for my application. I need that 2” of total travel range, but for measuring 0.5” is sufficient. So my question: is deck parallelism at 0.5” movement also <250µm or even less? My tolerance is <100µm, is that realizable with your system?
bdada  (posted 2011-11-15 18:44:00.0)
Response from Buki at Thorlabs.com Thank you for your feedback. The 1mm/sec velocity is what we specify to ensure positional accuracy. We have contacted you to discuss if other products may be more suitable. For instance, the combination of LTS150 - Integrated 150 mm Travel Stage with a LTSP2 - Z-Axis Bracket would provide 3mm/s vertical velocity with a maximum vertical load capacity of 4kg, with 150mm of travel. Or the LNR50S - 2" TravelMax Stage with Trapezoidal Stepper and LNR50P2 bracket would provide a maximum velocity of 8mm/s and a maximum vertical load capacity of 10kg, but limited to only 2” of travel. We have contacted you to provide further support.
excelkim.kim  (posted 2011-11-11 06:24:57.0)
I have serious problem. max. 1mm/sec velocity is so slow. It takes too much time to enter the target position. Is there any method to increase the velocity. At your specification, max. rpm is over 700. I think you could give me the solution. Thank you.
bdada  (posted 2011-09-16 12:33:00.0)
Response from Buki at Thorlabs: The L490MZ is designed such that it will not drop when it is unplugged from the power supply. Please contact TechSupport@thorlabs.com if you have further questions.
felipe.aguilarsan  (posted 2011-09-15 17:12:50.0)
Hello, I want to know if this product have something like "self locking at rest" for unplugged use in a determined position, thank you.
user  (posted 2011-09-14 18:39:47.0)
Supose I put a position X, if I unplug or turn off this device it will keep the same position rigidly? Like a self locking or something like that.
jjurado  (posted 2011-05-20 13:54:00.0)
Response from Javier at Thorlabs to gerbenjoshua: Thank you very much for contacting us. We have not developed drivers and documentation for interfacing our motorized stages with the Linux platform.
gerbenjoshua  (posted 2011-05-20 14:53:07.0)
Are Linux drivers available?
bdada  (posted 2011-03-09 16:04:00.0)
Response from Buki: Thank you for using our feedback tool. The L490MZ is anodized so it is not vacuum compatible. However, we have offered unanodized L490 lab jacks as custom products before. I will contact you directly to discuss your appliction and determine if an unanodized L490MZ is feasible.
paulgard  (posted 2011-03-08 19:57:25.0)
Is L490-MZ vacuum compatible?

Motorized Linear Translation Stages

Thorlabs' motorized linear translation stages are offered in a range of maximum travel distances, from a stage with 20 µm of piezo translation to our 600 mm direct drive stage. Many of these stages can be assembled in multi-axis configurations, providing XY or XYZ translation. For fiber coupling applications, please see our multi-axis stages, which offer finer adjustment than our standard motorized translation stages. In addition to motorized linear translation stages, we offer motorized rotation stages, pitch and yaw platforms, and goniometers. We also offer manual translation stages.

Piezo Stages

These stages incorporate piezoelectric elements in a variety of drive mechanisms. Our Nanoflex™ translation stages use standard piezo chips along with manual actuators. Our LPS710E z-axis stage features a mechanically amplified piezo design and includes a matched controller. The PD1 stage incorporates a piezo inertia drive that uses "stick-slip" friction properties to obtain an extended travel range. The Elliptec™ stages use resonant piezo motors to push and pull the moving platform through resonant elliptical motion.

Piezoelectric Stages
Product Family Nanoflex™ 20 µm Stage
with 5 mm Actuator
Nanoflex™ 25 µm Stage
with 1.5 mm Actuator
LPS710E 1.1 mm
Z-Axis Stage
PD1 20 mm Stage Elliptec™ 28 mm Stage Elliptec™ 60 mm Stage
Click Photo
to Enlarge
Travel 20 µm + 5 mm Manual 25 µm + 1.5 mm Manual 1.1 mm 20 mm 28 mm 60.0 mm
Maximum Velocity - - 3 mm/s 180 mm/s 90 mm/s
Drive Type Piezo with Manual Actuator Amplified Piezo Piezoelectric Inertia Drive Resonant Piezoelectric Motor
Possible Axis
Configurations
X, XY, XYZ - X, XY, XYZ X
Additional Details

Stepper Motor Stages

These translation stages feature removable or integrated stepper motors and long travel ranges up to 300 mm. The MLJ150 stage also offers high load capacity vertical translation. The other stages can be assembled into multi-axis configurations.

Stepper Motor Stages
Product Family LNR Series
25 mm Stage
LNR Series
50 mm Stage
MLJ150 50 mm
Vertical Stage
NRT Series
100 mm Stage
NRT Series
150 mm Stage
LTS Series
150 mm Stage
LTS Series
300 mm Stage
Click Photo
to Enlarge
Travel 25 mm 50 mm 50 mm 100 mm 150 mm 150 mm 300 mm
Maximum Velocity 2.0 mm/s 50 mm/s 3.0 mm/s 30 mm/s 50 mm/s
Possible Axis
Configurations
X, XY, XYZ X, XY, XYZ - X, XY, XYZ X, XY, XYZ
Additional Details

DC Servo Motor Stages

Thorlabs offers linear translation stages with removable or integrated DC servo motors. These stages feature low profiles and can be assembled in multi-axis configurations.

DC Servo Motor Stages
Product Family MT Series 12 mm Stages PT Series 25 mm Stages MTS Series 25 mm Stage MTS Series 50 mm Stage KVS30 30 mm Vertical Stage
Click Photo to Enlarge
Travel 12 mm 25 mm 25 mm 50 mm 30 mm
Maximum Velocity 2.6 mm/s 2.4 mm/s 8.0 mm/s
Possible Axis Configurations X, XY, XYZ X, XY, XYZ -
Additional Details

Direct Drive Stages

These low-profile stages feature integrated brushless DC servo motors for high speed translation with zero backlash. When no power is applied, the platforms of these stages have very little inertia and are virtually free running. Hence these stages may not be suitable for applications where the stage's platform needs to remain in a set position when the power is off. We do not recommend mounting these stages vertically.

Direct Drive Stages
Product Family DDS Series
220 mm Stage
DDS Series
300 mm Stage
DDS Series
600 mm Stage
Click Photo to Enlarge
Travel 220 mm 300 mm 600 mm
Maximum Velocity 300 mm/s 400 mm/s 400 mm/s
Possible Axis Configurations X, XY X X
Additional Details

Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Imperial Price Available
MLJ150 Support Documentation
MLJ150Motorized High-Load Vertical Translation Stage, 50 mm Travel, 1/4"-20 Taps
$3,368.30
Lead Time
+1 Qty Docs Part Number - Metric Price Available
MLJ150/M Support Documentation
MLJ150/MMotorized High-Load Vertical Translation Stage, 50 mm Travel, M6 Taps
$3,368.30
Lead Time
Last Edited: Sep 23, 2013 Author: Paul Daintith