Vytran® Fiber Recoaters with UV Curing LEDs
- Recoat Spliced Fibers for Full Protection and Flexibility
- UV Curing LEDs Provide Fast Curing Times and Long Lifetimes
- Available with Manual or Automatic Mold Assembly and Recoat Injector
PTR404B
100 mm Fiber Recoater with
Manual Recoat Injector
PTR305
50 mm Fiber Recoater with Automatic
Mold Assembly and Recoat Injector
RM430UVA
50 mm Mold Assembly for
Manual Recoaters
(Sold Separately)
VHJT
Fiber Holding Block Top Insert (Sold Separately)
VHV400
Fiber Holding Block Bottom Insert for Ø400 µm Fiber (Sold Separately)
Please Wait
Building a Complete Fiber Processing System?
To build a complete system, you will need to purchase a base unit plus additional components that are dependent upon the size of the fiber being processed. We recommend that you contact us prior to ordering for assistance with choosing a system and all the necessary components. This also allows us to install and factory-align all system components within the base unit prior to shipping, ensuring optimal performance out-of-the-box.
To take advantage of this assistance, please e-mail us directly at techsupport@thorlabs.com and a representative will contact you shortly.
Fiber Recoaters with UV Curing LEDs | |||
---|---|---|---|
Item # | Mold Assembly |
Recoat Injector |
Max Recoat Length |
PTR305 | Automatic | Automatic | 50 mm |
PTR403 | Manual | Automatic | 50 mm |
PTR403B | Manual | Manual | 50 mm |
PTR404B | Manual | Manual | 100 mm |
Click to Enlarge
Thorlabs' PTR403B Fiber Recoater Indicating the Mold Assembly, Fiber Holding Blocks, and Inserts
Features
- Recoat Fusion-Spliced Fibers to Protect Splice and Restore Flexibility
- Four Manual and Automatic System Options
- Fully Programmable Using the Included Controller
- Push Buttons on Recoaters Start and Stop Recoat Process
- Durable Quartz Mold Plate Capable of >10 000 Recoats
- Replacement Components Sold Separately Below
Thorlabs' Vytran® Fiber Recoaters restore the coating to a fusion-spliced fiber. The recoat material is injected through a cross-channel in the top plate into the mold assembly and then cured by ultraviolet (UV) LEDs. The LEDs provide faster cure times and longer lifetimes than the halogen lamps used in other fiber recoaters. One recoater with an automatic mold assembly is available; other recoaters use manual mold assemblies. Our automatic recoater utilizes a pneumatic mold assembly that directly injects recoat material into the mold cavity while our manual recoaters use a hinged top that can be opened and closed by hand. Both the automatic and manual recoaters use a split-quartz mold. The mold's surface is coated to prevent any recoat material that migrates between the plates from curing and forming imperfections on the finished recoat.
Each recoater uses a volumetric dispensing pump to inject the recoat material into the mold cavity; the PTR305 and PTR403 recoaters incorporate automatic injection systems while the PTR403B and PTR404B recoater have manual injection systems. The recoated fiber is then cured by UV LEDs integrated within the mold assembly housing. The fiber recoating process restores the buffer coating to a stripped fiber, giving it the same flexibility as when originally manufactured. Unlike standard heat shrink protection sleeves, a recoated fiber can be handled and coiled normally, without risking the fusion-spliced section of fiber.
The recoat process starts with the fusion-spliced section of fiber being placed in the middle of the mold assembly. Once set in position, inserts in the fiber holding blocks secure the spliced fiber in place. Recoat material is pumped into the cavity and then UV-cured. Due to their ability to restore a fusion-spliced fiber to original condition, fiber recoaters are ideal for manufacturing high-stress or sensitive fibers such as undersea optical fiber cables, submarine communication cabling, fiber lasers, or Distributed Bragg Reflector (DBR) lasers.
We also offer fiber recoaters with halogen lamps for curing the fiber.
Mold Assemblies
The PTR305 automatic recoater comes standard with a mold assembly for Ø430 µm coated fibers. For our recoaters using manual mold assemblies, the mold assemblies are sold separately so that customers can choose the right mold for the coating diameter in their application. Custom mold coating sizes are available up to Ø900 µm. Pre-installation of the mold assembly at the factory is also available. Contact Tech Support for more information on custom molds or factory assembly.
Inserts for Fiber Holding Blocks
In addition to the above, we offer a variety of inserts for use in the fiber holding blocks of the recoaters in order to support a wide range of fiber coating diameters; a total of four inserts are necessary for each recoater (two top inserts and two bottom inserts). See the subgroup below for details.
Recoat Materials
Thorlabs offers both high-index (Item # AB950200) and low-index (Item # PC373) recoat materials for use in these recoaters. Recoaters with manual injection pumps (Item #s PTR403B and PTR404B) are compatible with both types of recoat material; the automatic injection pump of the PTR305 and PTR403 recoaters is compatible with the high-index material only. The automatic injector can be customized to work with both the low- and high-index recoat material; please contact Tech Support for more information.
Item # | PTR305 | PTR403 | PTR403B | PTR404B |
---|---|---|---|---|
Recoater Type | Automatic | Manual | ||
Recoater Mold | Pneumatic Split Quartz Platesa | Hinged Split Quartz Plates | ||
Recoat Diameterb | 430 µm | 280 µm, 430 µm, or 600 µmc | ||
UV Curing Source | 32 UV LEDs | 14 UV LEDs (Integrated in Mold Assembly) |
28 UV LEDs (Integrated in Mold Assembly) |
|
Maximum Recoat Length |
50 mm | 100 mm | ||
Recoat Material | High-Index UV Curable Acrylate | High- or Low-Index UV Curable Acrylate | ||
Recoat Injection | Automatic | Manuald | Manuale | |
Recoat Volume | Programmable (µL) | Manual | ||
Recoat Injection Rate | Programmable (≤1.8 µL/s) | Manual | ||
Cure Timef | 17 s (Typical) | 15 s (Typical) | 16 s (Typical) | |
Mold Cleaning Requirementg |
At Start Up and Shut Downh | After Every Recoat | ||
Total Cycle Time | 45 s (Typical) | 60 s (Typical) | ||
Dimensions (L × W × H) |
10.14" × 5.77" × 6.50" (257.6 mm × 146.7 mm × 165.1 mm) |
10.14" × 5.30" × 6.88" i (257.4 mm × 134.6 mm × 174.8 mm) |
10.13" × 5.30" × 7.13" i (257.4 mm × 134.6 mm × 181.2 mm) |
|
AC Power | 110 - 120 V / 200 - 240 V, 47-63 Hz | 100 - 240 VAC; 47 - 63 Hz | ||
Controller Type | Handset (Item # VYT300C) |
The VYT300C handset controller is shipped with the recoaters sold below. One handset controller can be used to configure parameters on multiple fiber processing units in succession. Full instructions for using the handset controller can be found in the manual for each device. The screenshots below highlight key features of the graphical user interface.
Click to Enlarge
The initial screen on the VYT300C Handset Controller gives the option to begin curing. Other menus can be accessed by swiping the touchscreen left or right, or by tapping the options at the top of the screen.
Click to Enlarge
While curing, the controller displays the parameters defined on the Edit tab and the progress of the cure. The Stop button can be used to end the active cure.
Click to Enlarge
The Recoat screen will also show the status of any macro that the device is currently running.
Click to Enlarge
The Edit menu allows the user to set inject parameters, such as quantity, rate, shrink time, and purge cycles; these settings are available only when using the PTR403. Cure parameters on both PTR403 and PTR403B include start and stop times for each pair of UV curing LEDs, as well as LED power.
Click to Enlarge
The suite of tools available through the handset controller includes a record of the total cure time of the machine (under Process Counters) that is not shown on the tablet controller. See the manuals of the compatible fiber recoaters for more information on these tools.
Click to Enlarge
The handset controller can open, save, delete, export, and import files containing parameters for compatible systems. Exporting or importing a file will require a memory device to be connected to the Program Port of the handset controller.
Product DemonstrationsThorlabs has demonstration facilities for the Vytran® fiber glass processing systems offered on this page within our Morganville, New Jersey; Shanghai, China; and Exeter, Devonshire offices. We invite you to schedule a visit to see these products in operation and to discuss the various options with a fiber processing specialist. Please schedule a demonstration at one of our locations below by contacting technical support. We welcome the opportunity for personal interaction during your visit! Thorlabs Vytran Europe
|
Posted Comments: | |
No Comments Posted |
The table below outlines the entire PTR series to directly compare the capabilities across the whole line.
Vytran® PTR Series Recoater and Proof Tester Selection Guide | ||||||||
---|---|---|---|---|---|---|---|---|
Item # | UV Curing Source | Mold Assembly | Proof Tester | Recoat Injection Pump | Max Recoat Length | Recoat Material | Mold Cleaning Requirement | |
High Index (Item # AB950200) |
Low Index (Item # PC373) |
|||||||
Dedicated Proof Testers | ||||||||
PTR301 | N/A | N/A | Linear | N/A | N/A | - | - | N/A |
PTR302 | Rotary | - | - | |||||
Dedicated Recoatersa | ||||||||
PTR303 | Halogen Lamps | Manual | N/A | Automatic | 50 mm | - | After Every Recoat Process | |
PTR303B | Manual | 50 mm | ||||||
PTR403 | LEDs | Manual | N/A | Automatic | 50 mm | - | After Every Recoat Process | |
PTR403B | Manual | 50 mm | ||||||
PTR404B | Manual | 100 mm | ||||||
PTR304 | Halogen Lamps | Manual | N/A | Automatic | 100 mm | - | After Every Recoat Process | |
PTR304B | Manual | 100 mm | ||||||
PTR305 | LEDs | Automatic | N/A | Automatic | 50 mm | - | Dailyb | |
Recoaters with Proof Testersa | ||||||||
PTR306 | Halogen Lamps | Manual | Linear | Automatic | 50 mm | - | After Every Recoat Process | |
PTR306B | Manual | 50 mm | ||||||
PTR406 | LEDs | Manual | Linear | Automatic | 50 mm | - | After Every Recoat Process | |
PTR406B | Manual | 50 mm | ||||||
PTR307 | Halogen Lamps | Manual | Rotary | Automatic | 50 mm | - | After Every Recoat Process | |
PTR307B | Manual | 50 mm | ||||||
PTR407 | LEDs | Manual | Rotary | Automatic | 50 mm | - | After Every Recoat Process | |
PTR407B | Manual | 50 mm | ||||||
PTR308 | LEDs | Automatic | Linear | Automatic | 50 mm | - | Dailyb |
Included
- Automatic Fiber Recoater
- Pneumatic Mold Assembly for Ø430 µm Coatings
- Quick Snap-On Connectors for Compressed Air Source
- Location-Specific Power Cord
- Handset Controller
- 1/8" Outer Diameter Pressure Supply Tubing and Fittings Kit
Must be Purchased Separately
- Fiber Holding Block Top Inserts (Two Required)
- Fiber Holding Block Bottom Inserts (Two Required)
- High-Index Recoat Material (One Bottle Required)
- 80 - 120 psi Compressed Air/Gas Source (Not Available from Thorlabs)
- Available Standard for Ø430 µm Coatings
- 50 mm Maximum Recoat Length
- Compatible with High-Index Recoat Material
- Ideal for Medium- to High-Volume Manufacturing
Thorlabs' Automatic Fiber Recoater completely automates the fiber recoat process; fully programmable, it can be operated either through the handset controller (which gives full programming capabilities) or via buttons on the top of the machine.
Our PTR305 Automatic Fiber Recoater uses a pneumatic mold assembly to control the mold plates. This design allows the recoat material to be directly injected into the mold cavity, eliminating any excess material, which would require cleaning after every recoat. Additionally, once the fiber is secured in the fiber holding blocks, the entire recoat process is performed automatically. This clean, automated process makes the PTR305 ideal for high-volume manufacturing. This recoater is designed for fiber coatings of Ø430 µm and requires the purchase of fiber block inserts (sold below). Choose the inserts that match the coating diameter of the fiber being used. It is compatible with high-index recoat material only (sold below). The pneumatic design of the mold assembly requires an external 80 - 120 psi compressed air source (not available from Thorlabs).
A handset controller, which comes standard with the PTR305, allows the user to control and program the unit. All recoat parameters can be set through this controller.
Customized mold sizes for recoat diameters up to 900 µm are available; please contact Tech Support for more information.
Included
- Fiber Recoater
- Location-Specific Power Cord
- Handset Controller
Must be Purchased Separately
- Mold Assembly (One Required)
- Fiber Holder Top Inserts (Two Required)
- Fiber Holder Bottom Inserts (Two Required)
- High-Index Recoat Material (One Bottle Required)
Replacement Parts
- Injection Tube
- Compatible with Mold Assemblies for Coating Diameters of 280 µm, 430 µm, or 600 µm
- 50 mm Maximum Recoat Length
- Compatible with High-Index Recoat Material
- Ideal for Low-Volume Manufacturing and R&D
The PTR403 fiber recoater uses a hinged mold assembly (sold separately below) to form the mold cavity for recoating. This design allows the recoat material to be injected through a cross-channel in the mold's top plate. Intended for low-volume manufacturing and R&D applications, the mold assembly can be easily swapped out and the process parameters can be easily changed, providing flexibility and adaptability, but the mold assembly requires cleaning between each recoat process.
This recoater features an automated pump to inject the recoat material. The amount of material dispensed by the automatic injector is controlled by hand via the top-mounted "Inject" button or programmed into the machine by the included VYT300C controller. The automatic injector is only compatible with high-index recoat material (sold below); however, an add-on unit that can use both low- and high-index recoat materials is available. Please contact Tech Support for more information.
When purchasing a fiber recoater, both a mold assembly and a set of appropriately sized fiber holding block inserts must be purchased separately. A handset controller is included with the PTR403 recoater.
Mold Assembly
Compatible mold assemblies are available for coating diameters of 280 µm, 430 µm, and 600 µm. Customized recoat diameters up to 900 µm are also available; please contact Tech Support for more information. The UV curing LEDs are housed within the mold assemblies for the PTR403 recoater; there is no UV curing source within the unit itself. See compatible mold assemblies below.
Fiber Holding Block Inserts
A total of four inserts (two top and two bottom) are required for the recoater unit. Inserts are available for fiber diameters from 80 µm to 1000 µm. See compatible fiber holding block inserts below.
Included Controller
The PTR403 recoater is shipped with the VYT300C handset controller, which allows the user to program and control the recoater unit. Adjustable settings include the inject rate, inject amount, cure time, lamp power, and programming custom recipes. An injection calculator provides an estimate of recoat parameters that can be refined by the user. Please see the Controller tab for details.
Included
- Fiber Recoater
- Location-Specific Power Cord
- Handset Controller
Must be Purchased Separately
- Mold Assembly (One Required)
- Fiber Holder Top Inserts (Two Required)
- Fiber Holder Bottom Inserts (Two Required)
- High- or Low-Index Recoat Material (One Bottle Required)
Replacement Parts
- Manual Injector
- Injection Tube
- Syringe Barrel
Click to Enlarge
The PTR404B has a maximum recoat length of 100 mm, while the PTR403B has a maximum recoat length of 50 mm.
- Compatible with Mold Assemblies for Coating Diameters of 280 µm, 430 µm, or 600 µm
- 50 mm or 100 mm Maximum Recoat Length
- Ideal for Low-Volume Manufacturing and R&D
- Compatible with High- and Low-Index Recoat Material
These fiber recoaters use a hinged mold assembly (sold separately below) to form the mold cavity for recoating. This design allows the recoat material to be injected through a cross-channel in the mold's top plate. Intended for low-volume manufacturing and R&D applications, the mold assembly can be easily swapped out and the process parameters can be easily changed, providing flexibility and adaptability, but the mold assembly requires cleaning between each recoat process.
Each recoater features a manual recoat injection system. The user is required to dispense the recoat material into the mold cavity. This manual injection system is compatible with both low- and high-index recoat material (sold separately below). Additionally, replacement injectors are available below.
When selecting ones of these recoaters, both a mold assembly and a set of appropriately sized fiber holding block inserts must be chosen. A handset controller is included with the each recoater.
Mold Assembly
Compatible mold assemblies are available for coating diameters of 280 µm, 430 µm, and 600 µm. Customized recoat diameters up to 900 µm are also available; please contact Tech Support for more information. The UV curing LEDs are housed within the mold assemblies for these recoaters; there is no UV curing source within the unit itself. See compatible mold assemblies below. Separate mold assemblies are available for 50 mm and 100 mm fiber recoaters.
Fiber Holding Block Inserts
A total of four inserts (two top and two bottom) are required for the recoater unit. Inserts are available for fiber diameters from 80 µm to 1000 µm. See compatible fiber holding block inserts below.
Included Controller
Each recoater is shipped with the VYT300C handset controller, which allows the user to program and control the recoater unit. Adjustable settings include the inject rate, inject amount, cure time, lamp power, and programming custom recipes. An injection calculator provides an estimate of recoat parameters that can be refined by the user. Please see the Controller tab for details.
Item # | Coating Diameter |
Max Recoat Length |
Compatible Recoatersa |
---|---|---|---|
RM280UVA | 280 µm | 50 mm | PTR403 PTR403B |
RM430UVA | 430 µm | ||
RM600UVA | 600 µm | ||
RM280UVL | 280 µm | 100 mm | PTR404B |
RM430UVL | 430 µm | ||
RM600UVL | 600 µm |
- Compatible with UV LED Fiber Recoaters
- UV LEDs Integrated Inside Mold Assembly Housing
- Three Available Mold Coating Diameters: 280 µm, 430 µm, and 600 µm
- 50 mm or 100 mm Maximum Recoat Length
The Mold Assemblies are composed of split quartz mold plates which, when closed, form the cylindrical mold cavity around the exposed section of the fiber being recoated. They are available for Ø280 µm, Ø430 µm, or Ø600 µm fiber coatings and in maximum fiber recoat lengths of 50 mm (compatible with Item #s PTR403 and PTR403B) or 100 mm (compatible with Item # PTR404B). Custom mold sizes up to Ø900 µm are available; please contact Tech Support for more information. Mold assemblies with a 50 mm recoat length feature a lever to assist with opening or closing the mold.
Recoat material (sold below) is injected into the mold assembly by either an automatic or manual injection system. Then, UV light from the integrated LEDs cures the recoat material. Cure times range from 15 s to 90 s depending on mold size and recoat material. The recoater mold assembly should be cleaned throughly with isopropyl alcohol or acetone between each recoating process; reliable and repeatable performance is highly dependent on the cleanliness of the mold.
When purchasing a manual fiber recoater for the first time, it is necessary to choose a mold assembly that is appropriate for the chosen recoater and desired fiber coating diameter. Additional mold assemblies may also be purchased and swapped out by the user. The assembly simply screws to the top of the device, making the removal and install simple and easy. Because of this, our manual recoaters are adaptable and flexible in the field and can be modified to accept varying diameters of fiber quickly. A recoater mold can be factory installed prior to shipment upon request by contacting Tech Support. It is also necessary to order the proper inserts (sold below) that best match the fiber diameter being used, whether purchasing a fiber recoater for the first time or updating a current recoater for a different fiber diameter.
Please note that these mold assemblies are only for the manual recoaters (Item #s PTR403, PTR403B, and PTR404B). Each PTR305 automatic recoater is sold with its own assembly already installed.
- Fiber Block Inserts for Thorlabs' Fiber Recoaters
- Two Versions Available:
- VHH Series Inserts for PTR305 Recoater
- VHJ and VHV Series Inserts for PTR403, PTR403B, & PTR404B Recoaters
- Choose Two Top Inserts and Two Bottom Inserts
- Replacement Strips for VHJT Insert Available Below
For all the recoaters sold above, the proper set of inserts needs to be selected. A total of four inserts (two top and two bottom) are required for one unit. The inserts are seated in slots in the fiber holding blocks and secured with setscrews (included with the recoater). They can easily be swapped out, allowing the recoaters to adapt quickly to clamp fibers with different coating diameters. Note that the mold assembly (available above) also needs to be changed if a different recoat diameter is desired.
We offer four types of inserts. The VHH series top inserts are fabricated from solid stainless steel, while the VHH series bottom inserts feature V-grooves and vacuum holes for accurate, repeatable positioning for recoating. The VHJT series top inserts incorporate a rubber strip that ensures sufficient friction to hold fiber under tension. The VHV series bottom inserts feature V-groove designs and vacuum holes for accurate, repeatable positioning for recoating.
Custom sizes are available; please contact Tech Support for more information.
Compatible Fiber Buffer/Coating Diameters & Recoaters | |||||
---|---|---|---|---|---|
Item # | Top or Bottom |
Nominal Diameter |
Min Diameter |
Max Diameter |
Compatible Recoatersa |
VHH000 | Top | - | 90 µm | 660 µm | PTR305 |
VHH900b | Top | 900 µm | 700 µm | 1000 µm | |
VHH100 | Bottom | 100 µm | 90 µm | 110 µm | |
VHH125 | Bottom | 125 µm | 113 µm | 137 µm | |
VHH160 | Bottom | 160 µm | 144 µm | 176 µm | |
VHH250 | Bottom | 250 µm | 225 µm | 275 µm | |
VHH300 | Bottom | 300 µm | 250 µm | 350 µm | |
VHH400 | Bottom | 400 µm | 350 µm | 450 µm | |
VHH500 | Bottom | 500 µm | 450 µm | 550 µm | |
VHH600 | Bottom | 600 µm | 540 µm | 660 µm | |
VHH900Sb | Bottom | 900 µm | 810 µm | 990 µm |
Compatible Fiber Buffer/Coating Diameters & Recoaters | |||||
---|---|---|---|---|---|
Item # | Top or Bottom |
Nominal Diameter |
Min Diameter |
Max Diameter |
Compatible Recoatersa |
VHJT | Top | - | 80 µm | 700 µm | PTR403(B) PTR404B |
VHJT900b | Top | 900 µm | 700 µm | 1000 µm | |
VHV100 | Bottom | 100 µm | 66 µm | 133 µm | |
VHV125 | Bottom | 125 µm | 83 µm | 167 µm | |
VHV160 | Bottom | 160 µm | 107 µm | 213 µm | |
VHV250 | Bottom | 250 µm | 167 µm | 333 µm | |
VHV300 | Bottom | 300 µm | 200 µm | 400 µm | |
VHV400 | Bottom | 400 µm | 266 µm | 533 µm | |
VHV500 | Bottom | 500 µm | 333 µm | 667 µm | |
VHV550 | Bottom | 550 µm | 367 µm | 733 µm | |
VHV600 | Bottom | 600 µm | 400 µm | 800 µm | |
VHV900b | Bottom | 900 µm | 600 µm | 1200 µm |
Item # | Recoat Material | Compatible Recoaters | |
---|---|---|---|
Automatic Injection | Manual Injection | ||
AB950200 | High Index | PTR303, PTR304, PTR305, PTR308, PTR403, PTR404, PTR406, PTR407 |
PTR303B, PTR304B, PTR403B, PTR404B, PTR406B, PTR407B |
PC373 | Low Index | - |
- AB950200: High-Index Recoat Material
- PC373: Low-Index Recoat Material
Thorlabs offers UV-curable acrylate recoat materials to be used in our PTR series fiber recoaters. We offer both high-index (Item # AB950200) and low-index (Item # PC373) material in 1 oz bottles. The high-index material can be used in all recoaters (except the PRL201), whereas the low-index material can only be used in recoaters with the manual injection pump option.
Item # | Component Description |
Compatible Recoaters | |
---|---|---|---|
50 mm Recoaters | 100 mm Recoaters | ||
PTRRRM |
Manual Injector | PTR303B, PTR306B, PTR307B, PTR406B, PTR407B |
- |
PTRRRML |
- | PTR304B, PTR404B | |
RRMTA |
Injection Tube | PTR303B, PTR306B, PTR307B, PTR406B, PTR407B |
- |
RRMTAL | - | PTR304B, PTR404B | |
RRMS | Syringe Barrel | PTR303B, PTR306B, PTR307B, PTR406B, PTR407B |
PTR304B, PTR404B |
Click to Enlarge
The manual injector is mounted to the recoater via two 4-40 mounting screws.
- Replacement Manual Injectors for Dispensing Recoat Material into the Mold
- Accept PC373 and AB950200 Recoat Materials
- Replacement Injection Tubes for Recoaters with Manual Injectors
- Replacement Syringe Barrel for Manual Injectors
These manual injectors and injection tubes are available as replacement parts for Thorlabs' Vytran Fiber Recoaters with Manual Injectors; compatible systems are listed to the right. We also offer a replacement syringe barrel.
Each injector can be mounted to compatible fiber recoaters via two 4-40, 3/32" hex screws on the recoater housing (see photo to the right). To connect the injector to the recoater mold, tighten the connector at the end of the green plastic tubing, then loosen by a 1/4 turn to allow for rotation.
The injector is equipped with a distribution valve and two-position selection lever for directing the flow of recoat material. A knurled dispensing screw with an internal plunger acts as a syringe for the
Each injection tube and the RRMS syringe barrel are available as replacement parts for the manual injectors. The injection tube should be changed out if the knurl fitting breaks off the end, it leaks recoat material, or a clog forms that cannot be cleared with acetone. If the syringe no longer injects or an excessive number of air bubbles are visible in the recoat material (even after flushing the system), the syringe barrel should be replaced. A 5/16" thin spanner wrench is required for securing the syringe onto the recoat injector. Detailed installation instructions are provided in the support documentation, which can be found by clicking on the red documents icon () next to each item number.
Compatible Systems
- PTR303, PTR304, and PTR403 Manual Fiber Recoaters, Automatic Recoat Injector
- PTR306, PTR307, PTR406, and PTR407 Manual Fiber Recoaters with Proof Testers, Automatic Recoat Injector
- Replacement Injection Tube for Dispensing Recoat Material into the Mold
- Compatible with Vytran Fiber Recoaters with Manual Mold Assemblies that Use Automatic Injectors (See List to the Right)
- For Use with AB950200 and PC373 Recoat Materials
This replacement injection tube is compatible with Thorlabs' Vytran Fiber Recoaters that use Manual Mold Assemblies and Automatic Injection Systems (Item #s listed to the right). Though each system comes with an injection tube installed, it may need to be replaced if the knurled fitting breaks off the end, it leaks recoat material, or a clog forms that cannot be cleared with acetone.
Detailed installation instructions for the RRATA injection tube are provided in the support documentation, which can be found by clicking on the red documents icon () next to the item number.
Click for Details
VHJR Rubber Strip shown partially inserted into the metal channel of a VHJT Fiber Holding Block Insert.
- Replacement Rubber Strip for VHJT, VHJ250, and VHJ500 Fiber Holding Block Inserts
- 2" Length (Trim to Size)
- Available in a Pack of 12
This 12 Pack of Replacement Rubber Strips is directly compatible with our VHJT, VHJ250, and VHJ500 fiber holding block inserts. Although one rubber strip comes preinstalled in each insert, these can wear out over time and should be replaced when the holding block insert no longer withstands the applied proof test tension.
The rubber strip features a raised profile, and care must be taken during installation to ensure this profile sits above the metal channel of the insert. Detailed installation instructions are provided in the VHJR support documentation, which can be found by clicking on the red documents icon () next to the item number.
Click to Enlarge
Screenshot of VYT300C Controller When Used with PTR403 Recoater
Compatible Systems
- LDC401(A) Fiber Cleavers
- LDC450B Portable Fiber Cleaver
- PTR303(B), PTR304(B), PTR306(B), PTR307(B), PTR403(B), PTR404B, PTR406(B), and PTR407(B) Manual Mold Fiber Recoaters
- PTR305 and PTR308 Automatic Mold Fiber Recoaters
- PTR301 and PTR302 Fiber Proof Tester
- Provides Full Functionality for Compatible Systems (See Compatible Systems List to the Right)
- Intuitive GUI
- Capacitive Touchscreen
- Small Footprint
This handset controller is available as an alternative to the tablet controller previously included with our Vytran Large Diameter Fiber Cleavers, PTR Series Fiber Recoaters, and PTR Series Fiber Proof Testers. One handset controller is included with each new PTR series recoater system. A single handset controller can be used with multiple systems; after configuring parameters for one fiber processing unit, the controller can be disconnected and then connected to a different unit, of the same or a different type, to configure its parameters.
The handset controller must be connected via the included cable in order to use it. The controller automatically turns on when the connected system is turned on. Upon startup, the handset controller will always read parameters from the connected system; i.e., the parameters that appear on the screen will always be the parameters that have been uploaded to the connected unit. If the parameters read from the unit match the parameters of the most recently opened file on the handset controller, the screen will display the file name.
The suite of tools available through the handset controller includes a record of the total cure time of the machine (under Process Counters) that is not shown on the tablet controller. This value may be reset each time the bulbs are replaced.
The handset controller can open, save, delete, export, and import files containing parameters for compatible systems. Exporting or importing a file will require a memory device to be connected to the Program Port of the handset controller.
Instructions for using this controller can be found in the manuals for the compatible Vytran systems.