Unmounted N-BK7 Reflective Neutral Density Filters


  • Optical Densities from 0.1 to 4.0
  • N-BK7 Substrate with Inconel Coating
  • Attenuation for the 350 - 1100 nm Range

ND230B

50 mm x 50 mm

ND501B

Ø1/2"

ND10B

Ø25 mm

ND2R40B

Ø2"

ND05B Filter in an
LMR1 Lens Mount

Related Items


Please Wait
Neutral Density Filter
Selection Guide
Absorptive
Uncoated
(400 - 650 nm)
Mounted
Unmounted
Uncoated
(1000 - 2600 nm)
Mounted
Unmounted
AR Coated
(350 - 700 nm)
Mounted
Unmounted
AR Coated
(650 - 1050 nm)
Mounted
Unmounted
AR Coated
(1050 - 1700 nm)
Mounted
Unmounted
Variable
Reflective
UV Fused Silica
(200 - 1200 nm)
Mounted
Unmounted
N-BK7
(350 - 1100 nm)
Mounted
Unmounted
ZnSe
(2 - 16 µm)
Mounted
Unmounted
Wedged UVFS (200 - 1200 nm)
Wedged N-BK7 (350 - 1100 nm)
Variable
Neutral Density Filter Kits
Optic Cleaning Tutorial

Features

  • Ø1/2", Ø25 mm, Ø50 mm, and 50 mm Square Unmounted Filters
  • Attenuates Over the 350 to 1100 nm Wavelength Range
  • Optical Densities Ranging from 0.1 to 4.0

Thorlabs' Reflective Neutral Density (ND) Filters provide uniform attenuation over the broad spectral range from 350 to 1100 nm. These metallic filters have optical densities ranging from 0.1 to 4.0; refer to the Specs tab above for detailed information about the average transmission obtained with each of our reflective neutral density filters. The Graphs tab contains plots of the transmission and reflection for each filter for a broad wavelength range.

These filters consist of an N-BK7 glass substrate with a metal (Inconel) coating deposited on one side. Inconel is a metallic alloy that ensures flat spectral response from the UV to the near IR. Unprotected metal coatings like this should only be cleaned by blown air, never touched, as contact may cause scratching to the unprotected surface. Although these are reflective ND filters, the Inconel coating does absorb some of the incident light, which limits the use of these filters to low-power applications. Inconel is resistant to aging under normal conditions; however, it will oxidize at elevated temperatures. To prevent oxidation, Thorlabs recommends using these ND filters at temperatures below 100 °C. To achieve the best performance, light should be incident on the side with the Inconel coating.

Our Ø1/2", Ø25 mm, and Ø50 mm N-BK7 reflective ND filters are also available mounted in SM05-, SM1-, or SM2-threaded lens tubes, respectively. Thorlabs also offers UV fused silica and variable reflective ND filters, as well as a complete line of absorptive ND filters in several sizes; the Selection Guide table to the right contains links to all of the available options.

Optical Density and Transmission
Optical density (OD) indicates the attenuation factor provided by an optical filter, i.e. how much it reduces the optical power of an incident beam. OD is related to the transmission, T, by the equation

Optical Density Equation

where T is a value between 0 and 1. Choosing an ND filter with a higher optical density will translate to lower transmission and greater absorption of the incident light. For higher transmission and less absorption, a lower optical density would be appropriate. As an example, if a filter with an OD of 2 results in a transmission value of 0.01, this means the filter attenuates the beam to 1% of the incident power. Please note that the transmission data for our neutral density filters is provided in percent (%).

Please note that these products are not designed for use as laser safety equipment. For lab safety, Thorlabs offers an extensive line of safety and blackout products, including beam blocks, that significantly reduce exposure to stray light.

General Specifications
Filter ND5xxB NDxxB ND2RxxB ND2xxB
Substrate N-BK7a
Size Ø12.7 mm Ø25.0 mm Ø50.0 mm 50.0 mm x 50.0 mm
Dimensional Tolerance +0.0 / -0.20 mm +0.0 / -0.20 mm
Thickness 1.0 ± 0.25 mm 1.0 ± 0.10 mm 2.0 ± 0.10 mm
Clear Aperture >90% of Outer Diameter >45.0 mm x 45.0 mm
Surface Accuracy/Flatness
<2λ <2λb <2λc
Surface Quality 40-20 Scratch-Dig
Parallelism <20 arcmin <30 arcsec
Optical Density Tolerance ±5.0%
  • Click Link for Detailed Specifications on the Substrate
  • Over a Ø25.0 mm Area
  • Over a 25.0 mm x 25.0 mm Area
Optical Density Damage Thresholds
0.3 CWa 16 W/cm (532 nm, Ø0.051 mm)
Pulsed 0.025 J/cm2 (532 nm, 10 ns, 10 Hz, Ø0.493 mm)
1.0 CWa 5 W/cm (532 nm, Ø0.019 mm)
Pulsed 0.025 J/cm2 (532 nm, 10 ns, 10 Hz, Ø0.566 mm)
2.0 CWa 10 W/cm (532 nm, Ø0.365 mm)
Pulsed 0.025 J/cm2 (532 nm, 10 ns, 10 Hz, Ø0.493 mm)
  • The power density of your beam should be calculated in terms of W/cm. For an explanation of why the linear power density provides the best metric for long pulse and CW sources, please see the Damage Thresholds tab.


For Detailed Plot Information
 For More Info For individual transmission and optical density plots, as well as Excel files with raw data, click on this icon in the product tables below.
An Excel file with transmission and reflectance data for all N-BK7 Reflective ND filters is also available.
 Optical Density Transmission Reflectance
OD 0.1 - 0.6 Transmission OD 0.1 - 0.6
Click to Enlarge
Reflectivity OD 1.0 - 2.0
Click to Enlarge
OD 1.0 - 2.0 Transmission OD 0.1 - 0.6
Click to Enlarge
Visible transmission OD 1.0 - 2.0
Click to Enlarge
OD 3.0 - 4.0 Transmission OD 3.0 - 4.0
Click to Enlarge

Click for Transmission in the 400-700 nm Wavelength Range
Reflectivity OD 3.0 - 4.0
Click to Enlarge
Engraved Back of OAP
Click to Enlarge

Water Spectrum as Recorded Through a Standard and Wedged ND filter

Comparison of Standard and Wedged ND Filters
We present laboratory measurements on the difference in the etalon effect between our standard reflective neutral density (ND) filters and our wedged reflective ND filters. In many broadband scattering or absorption measurements, it is important to understand how intensity fluctuations through the utilized optics can impact the measurement. While it is known that parallel surfaces introduce significant wavelength-dependent intensity fluctuations, we find that utilizing a wedged geometry significantly reduces these etalon effects.

For our experiment we used the SLS202 Stabilized Light Source as the broadband, fiber-coupled light source. The F260FC-C Fiber Collimator, held in the KAD11F Kinematic Pitch/Yaw Adapter, collimates the light out of the fiber. The collimated light is incident upon the ND filter that is being investigated before entering the OSA203B Optical Spectrum Analyzer. The OSA has a spectral resolution of 7.5 GHz (0.25 cm-1) and the traces were averaged (>100 scans) in order to reduce noise and allow for more accurate analysis. The data focused on a wavelength range of 1820 - 1845 nm, which covers the NIR water spectrum. Since the absorption spectrum of water is well known, it is ideal to use as a comparison to evaluate the performance difference between these two styles of ND filter.

Lab Facts Complete Summary

The figure to the right summarizes the measured results for etalon effects through reflective neutral density filters. The etalon effects are quite stark, and we can see in the case of the standard ND filters that details of the water spectrum are lost to the intensity fluctuations of the background levels. By contrast, the wedged ND filters have a relatively clean signal with well-defined peaks. Data is presented for unmounted standard and wedged ND filters, though the results hold for mounted filters as well. Data is also compared to the HITRAN water spectrum standard. For details on the experimental setup employed and the results summarized here, please click here.

Damage Threshold Specifications
Optical Density Damage Thresholds
0.3 CWa 16 W/cm (532 nm, Ø0.051 mm)
Pulsed 0.025 J/cm2 (532 nm, 10 ns, 10 Hz, Ø0.493 mm)
1.0 CWa 5 W/cm (532 nm, Ø0.019 mm)
Pulsed 0.025 J/cm2 (532 nm, 10 ns, 10 Hz, Ø0.566 mm)
2.0 CWa 10 W/cm (532 nm, Ø0.365 mm)
Pulsed 0.025 J/cm2 (532 nm, 10 ns, 10 Hz, Ø0.493 mm)
  • The power density of your beam should be calculated in terms of W/cm. For an explanation of why the linear power density provides the best metric for long pulse and CW sources, please see the "Continuous Wave and Long-Pulse Lasers" section below.

Damage Threshold Data for Thorlabs' Reflective ND Filters

The specifications to the right are measured data for Thorlabs' reflective neutral density filters. Damage threshold specifications are constant for a given optical density coating, regardless of the size of the filter.

 

Laser Induced Damage Threshold Tutorial

The following is a general overview of how laser induced damage thresholds are measured and how the values may be utilized in determining the appropriateness of an optic for a given application. When choosing optics, it is important to understand the Laser Induced Damage Threshold (LIDT) of the optics being used. The LIDT for an optic greatly depends on the type of laser you are using. Continuous wave (CW) lasers typically cause damage from thermal effects (absorption either in the coating or in the substrate). Pulsed lasers, on the other hand, often strip electrons from the lattice structure of an optic before causing thermal damage. Note that the guideline presented here assumes room temperature operation and optics in new condition (i.e., within scratch-dig spec, surface free of contamination, etc.). Because dust or other particles on the surface of an optic can cause damage at lower thresholds, we recommend keeping surfaces clean and free of debris. For more information on cleaning optics, please see our Optics Cleaning tutorial.

Testing Method

Thorlabs' LIDT testing is done in compliance with ISO/DIS 11254 and ISO 21254 specifications.

First, a low-power/energy beam is directed to the optic under test. The optic is exposed in 10 locations to this laser beam for 30 seconds (CW) or for a number of pulses (pulse repetition frequency specified). After exposure, the optic is examined by a microscope (~100X magnification) for any visible damage. The number of locations that are damaged at a particular power/energy level is recorded. Next, the power/energy is either increased or decreased and the optic is exposed at 10 new locations. This process is repeated until damage is observed. The damage threshold is then assigned to be the highest power/energy that the optic can withstand without causing damage. A histogram such as that below represents the testing of one BB1-E02 mirror.

LIDT metallic mirror
The photograph above is a protected aluminum-coated mirror after LIDT testing. In this particular test, it handled 0.43 J/cm2 (1064 nm, 10 ns pulse, 10 Hz, Ø1.000 mm) before damage.
LIDT BB1-E02
Example Test Data
Fluence # of Tested Locations Locations with Damage Locations Without Damage
1.50 J/cm2 10 0 10
1.75 J/cm2 10 0 10
2.00 J/cm2 10 0 10
2.25 J/cm2 10 1 9
3.00 J/cm2 10 1 9
5.00 J/cm2 10 9 1

According to the test, the damage threshold of the mirror was 2.00 J/cm2 (532 nm, 10 ns pulse, 10 Hz, Ø0.803 mm). Please keep in mind that these tests are performed on clean optics, as dirt and contamination can significantly lower the damage threshold of a component. While the test results are only representative of one coating run, Thorlabs specifies damage threshold values that account for coating variances.

Continuous Wave and Long-Pulse Lasers

When an optic is damaged by a continuous wave (CW) laser, it is usually due to the melting of the surface as a result of absorbing the laser's energy or damage to the optical coating (antireflection) [1]. Pulsed lasers with pulse lengths longer than 1 µs can be treated as CW lasers for LIDT discussions.

When pulse lengths are between 1 ns and 1 µs, laser-induced damage can occur either because of absorption or a dielectric breakdown (therefore, a user must check both CW and pulsed LIDT). Absorption is either due to an intrinsic property of the optic or due to surface irregularities; thus LIDT values are only valid for optics meeting or exceeding the surface quality specifications given by a manufacturer. While many optics can handle high power CW lasers, cemented (e.g., achromatic doublets) or highly absorptive (e.g., ND filters) optics tend to have lower CW damage thresholds. These lower thresholds are due to absorption or scattering in the cement or metal coating.

Linear Power Density Scaling

LIDT in linear power density vs. pulse length and spot size. For long pulses to CW, linear power density becomes a constant with spot size. This graph was obtained from [1].

Intensity Distribution

Pulsed lasers with high pulse repetition frequencies (PRF) may behave similarly to CW beams. Unfortunately, this is highly dependent on factors such as absorption and thermal diffusivity, so there is no reliable method for determining when a high PRF laser will damage an optic due to thermal effects. For beams with a high PRF both the average and peak powers must be compared to the equivalent CW power. Additionally, for highly transparent materials, there is little to no drop in the LIDT with increasing PRF.

In order to use the specified CW damage threshold of an optic, it is necessary to know the following:

  1. Wavelength of your laser
  2. Beam diameter of your beam (1/e2)
  3. Approximate intensity profile of your beam (e.g., Gaussian)
  4. Linear power density of your beam (total power divided by 1/e2 beam diameter)

Thorlabs expresses LIDT for CW lasers as a linear power density measured in W/cm. In this regime, the LIDT given as a linear power density can be applied to any beam diameter; one does not need to compute an adjusted LIDT to adjust for changes in spot size, as demonstrated by the graph to the right. Average linear power density can be calculated using the equation below. 

The calculation above assumes a uniform beam intensity profile. You must now consider hotspots in the beam or other non-uniform intensity profiles and roughly calculate a maximum power density. For reference, a Gaussian beam typically has a maximum power density that is twice that of the uniform beam (see lower right).

Now compare the maximum power density to that which is specified as the LIDT for the optic. If the optic was tested at a wavelength other than your operating wavelength, the damage threshold must be scaled appropriately. A good rule of thumb is that the damage threshold has a linear relationship with wavelength such that as you move to shorter wavelengths, the damage threshold decreases (i.e., a LIDT of 10 W/cm at 1310 nm scales to 5 W/cm at 655 nm):

CW Wavelength Scaling

While this rule of thumb provides a general trend, it is not a quantitative analysis of LIDT vs wavelength. In CW applications, for instance, damage scales more strongly with absorption in the coating and substrate, which does not necessarily scale well with wavelength. While the above procedure provides a good rule of thumb for LIDT values, please contact Tech Support if your wavelength is different from the specified LIDT wavelength. If your power density is less than the adjusted LIDT of the optic, then the optic should work for your application. 

Please note that we have a buffer built in between the specified damage thresholds online and the tests which we have done, which accommodates variation between batches. Upon request, we can provide individual test information and a testing certificate. The damage analysis will be carried out on a similar optic (customer's optic will not be damaged). Testing may result in additional costs or lead times. Contact Tech Support for more information.

Pulsed Lasers

As previously stated, pulsed lasers typically induce a different type of damage to the optic than CW lasers. Pulsed lasers often do not heat the optic enough to damage it; instead, pulsed lasers produce strong electric fields capable of inducing dielectric breakdown in the material. Unfortunately, it can be very difficult to compare the LIDT specification of an optic to your laser. There are multiple regimes in which a pulsed laser can damage an optic and this is based on the laser's pulse length. The highlighted columns in the table below outline the relevant pulse lengths for our specified LIDT values.

Pulses shorter than 10-9 s cannot be compared to our specified LIDT values with much reliability. In this ultra-short-pulse regime various mechanics, such as multiphoton-avalanche ionization, take over as the predominate damage mechanism [2]. In contrast, pulses between 10-7 s and 10-4 s may cause damage to an optic either because of dielectric breakdown or thermal effects. This means that both CW and pulsed damage thresholds must be compared to the laser beam to determine whether the optic is suitable for your application.

Pulse Duration t < 10-9 s 10-9 < t < 10-7 s 10-7 < t < 10-4 s t > 10-4 s
Damage Mechanism Avalanche Ionization Dielectric Breakdown Dielectric Breakdown or Thermal Thermal
Relevant Damage Specification No Comparison (See Above) Pulsed Pulsed and CW CW

When comparing an LIDT specified for a pulsed laser to your laser, it is essential to know the following:

Energy Density Scaling

LIDT in energy density vs. pulse length and spot size. For short pulses, energy density becomes a constant with spot size. This graph was obtained from [1].

  1. Wavelength of your laser
  2. Energy density of your beam (total energy divided by 1/e2 area)
  3. Pulse length of your laser
  4. Pulse repetition frequency (prf) of your laser
  5. Beam diameter of your laser (1/e2 )
  6. Approximate intensity profile of your beam (e.g., Gaussian)

The energy density of your beam should be calculated in terms of J/cm2. The graph to the right shows why expressing the LIDT as an energy density provides the best metric for short pulse sources. In this regime, the LIDT given as an energy density can be applied to any beam diameter; one does not need to compute an adjusted LIDT to adjust for changes in spot size. This calculation assumes a uniform beam intensity profile. You must now adjust this energy density to account for hotspots or other nonuniform intensity profiles and roughly calculate a maximum energy density. For reference a Gaussian beam typically has a maximum energy density that is twice that of the 1/e2 beam.

Now compare the maximum energy density to that which is specified as the LIDT for the optic. If the optic was tested at a wavelength other than your operating wavelength, the damage threshold must be scaled appropriately [3]. A good rule of thumb is that the damage threshold has an inverse square root relationship with wavelength such that as you move to shorter wavelengths, the damage threshold decreases (i.e., a LIDT of 1 J/cm2 at 1064 nm scales to 0.7 J/cm2 at 532 nm):

Pulse Wavelength Scaling

You now have a wavelength-adjusted energy density, which you will use in the following step.

Beam diameter is also important to know when comparing damage thresholds. While the LIDT, when expressed in units of J/cm², scales independently of spot size; large beam sizes are more likely to illuminate a larger number of defects which can lead to greater variances in the LIDT [4]. For data presented here, a <1 mm beam size was used to measure the LIDT. For beams sizes greater than 5 mm, the LIDT (J/cm2) will not scale independently of beam diameter due to the larger size beam exposing more defects.

The pulse length must now be compensated for. The longer the pulse duration, the more energy the optic can handle. For pulse widths between 1 - 100 ns, an approximation is as follows:

Pulse Length Scaling

Use this formula to calculate the Adjusted LIDT for an optic based on your pulse length. If your maximum energy density is less than this adjusted LIDT maximum energy density, then the optic should be suitable for your application. Keep in mind that this calculation is only used for pulses between 10-9 s and 10-7 s. For pulses between 10-7 s and 10-4 s, the CW LIDT must also be checked before deeming the optic appropriate for your application.

Please note that we have a buffer built in between the specified damage thresholds online and the tests which we have done, which accommodates variation between batches. Upon request, we can provide individual test information and a testing certificate. Contact Tech Support for more information.


[1] R. M. Wood, Optics and Laser Tech. 29, 517 (1998).
[2] Roger M. Wood, Laser-Induced Damage of Optical Materials (Institute of Physics Publishing, Philadelphia, PA, 2003).
[3] C. W. Carr et al., Phys. Rev. Lett. 91, 127402 (2003).
[4] N. Bloembergen, Appl. Opt. 12, 661 (1973).

In order to illustrate the process of determining whether a given laser system will damage an optic, a number of example calculations of laser induced damage threshold are given below. For assistance with performing similar calculations, we provide a spreadsheet calculator that can be downloaded by clicking the button to the right. To use the calculator, enter the specified LIDT value of the optic under consideration and the relevant parameters of your laser system in the green boxes. The spreadsheet will then calculate a linear power density for CW and pulsed systems, as well as an energy density value for pulsed systems. These values are used to calculate adjusted, scaled LIDT values for the optics based on accepted scaling laws. This calculator assumes a Gaussian beam profile, so a correction factor must be introduced for other beam shapes (uniform, etc.). The LIDT scaling laws are determined from empirical relationships; their accuracy is not guaranteed. Remember that absorption by optics or coatings can significantly reduce LIDT in some spectral regions. These LIDT values are not valid for ultrashort pulses less than one nanosecond in duration.

Intensity Distribution
A Gaussian beam profile has about twice the maximum intensity of a uniform beam profile.

CW Laser Example
Suppose that a CW laser system at 1319 nm produces a 0.5 W Gaussian beam that has a 1/e2 diameter of 10 mm. A naive calculation of the average linear power density of this beam would yield a value of 0.5 W/cm, given by the total power divided by the beam diameter:

CW Wavelength Scaling

However, the maximum power density of a Gaussian beam is about twice the maximum power density of a uniform beam, as shown in the graph to the right. Therefore, a more accurate determination of the maximum linear power density of the system is 1 W/cm.

An AC127-030-C achromatic doublet lens has a specified CW LIDT of 350 W/cm, as tested at 1550 nm. CW damage threshold values typically scale directly with the wavelength of the laser source, so this yields an adjusted LIDT value:

CW Wavelength Scaling

The adjusted LIDT value of 350 W/cm x (1319 nm / 1550 nm) = 298 W/cm is significantly higher than the calculated maximum linear power density of the laser system, so it would be safe to use this doublet lens for this application.

Pulsed Nanosecond Laser Example: Scaling for Different Pulse Durations
Suppose that a pulsed Nd:YAG laser system is frequency tripled to produce a 10 Hz output, consisting of 2 ns output pulses at 355 nm, each with 1 J of energy, in a Gaussian beam with a 1.9 cm beam diameter (1/e2). The average energy density of each pulse is found by dividing the pulse energy by the beam area:

Pulse Energy Density

As described above, the maximum energy density of a Gaussian beam is about twice the average energy density. So, the maximum energy density of this beam is ~0.7 J/cm2.

The energy density of the beam can be compared to the LIDT values of 1 J/cm2 and 3.5 J/cm2 for a BB1-E01 broadband dielectric mirror and an NB1-K08 Nd:YAG laser line mirror, respectively. Both of these LIDT values, while measured at 355 nm, were determined with a 10 ns pulsed laser at 10 Hz. Therefore, an adjustment must be applied for the shorter pulse duration of the system under consideration. As described on the previous tab, LIDT values in the nanosecond pulse regime scale with the square root of the laser pulse duration:

Pulse Length Scaling

This adjustment factor results in LIDT values of 0.45 J/cm2 for the BB1-E01 broadband mirror and 1.6 J/cm2 for the Nd:YAG laser line mirror, which are to be compared with the 0.7 J/cm2 maximum energy density of the beam. While the broadband mirror would likely be damaged by the laser, the more specialized laser line mirror is appropriate for use with this system.

Pulsed Nanosecond Laser Example: Scaling for Different Wavelengths
Suppose that a pulsed laser system emits 10 ns pulses at 2.5 Hz, each with 100 mJ of energy at 1064 nm in a 16 mm diameter beam (1/e2) that must be attenuated with a neutral density filter. For a Gaussian output, these specifications result in a maximum energy density of 0.1 J/cm2. The damage threshold of an NDUV10A Ø25 mm, OD 1.0, reflective neutral density filter is 0.05 J/cm2 for 10 ns pulses at 355 nm, while the damage threshold of the similar NE10A absorptive filter is 10 J/cm2 for 10 ns pulses at 532 nm. As described on the previous tab, the LIDT value of an optic scales with the square root of the wavelength in the nanosecond pulse regime:

Pulse Wavelength Scaling

This scaling gives adjusted LIDT values of 0.08 J/cm2 for the reflective filter and 14 J/cm2 for the absorptive filter. In this case, the absorptive filter is the best choice in order to avoid optical damage.

Pulsed Microsecond Laser Example
Consider a laser system that produces 1 µs pulses, each containing 150 µJ of energy at a repetition rate of 50 kHz, resulting in a relatively high duty cycle of 5%. This system falls somewhere between the regimes of CW and pulsed laser induced damage, and could potentially damage an optic by mechanisms associated with either regime. As a result, both CW and pulsed LIDT values must be compared to the properties of the laser system to ensure safe operation.

If this relatively long-pulse laser emits a Gaussian 12.7 mm diameter beam (1/e2) at 980 nm, then the resulting output has a linear power density of 5.9 W/cm and an energy density of 1.2 x 10-4 J/cm2 per pulse. This can be compared to the LIDT values for a WPQ10E-980 polymer zero-order quarter-wave plate, which are 5 W/cm for CW radiation at 810 nm and 5 J/cm2 for a 10 ns pulse at 810 nm. As before, the CW LIDT of the optic scales linearly with the laser wavelength, resulting in an adjusted CW value of 6 W/cm at 980 nm. On the other hand, the pulsed LIDT scales with the square root of the laser wavelength and the square root of the pulse duration, resulting in an adjusted value of 55 J/cm2 for a 1 µs pulse at 980 nm. The pulsed LIDT of the optic is significantly greater than the energy density of the laser pulse, so individual pulses will not damage the wave plate. However, the large average linear power density of the laser system may cause thermal damage to the optic, much like a high-power CW beam.


Posted Comments:
曾 毛毛  (posted 2020-08-03 16:51:17.67)
请问吸收型和反射型中性密度衰减片是否适合在温度150度场景下使用?
YLohia  (posted 2020-08-03 11:23:03.0)
Thank you for contacting Thorlabs. An Applications Engineer from our team in China will reach out to you directly.
Hugo Feyrit  (posted 2020-05-29 10:54:22.723)
Hi, For my application, I need to know the refractive index (let say at around 500 nm) of the reflective optical density ND520B (not the one of the N-BK7 substrate). Could you please provide this information? Thanks
YLohia  (posted 2020-07-14 02:10:46.0)
Hello, thank you for contacting Thorlabs. The reflective material in these filters is Inconel and the index of refraction values for this can be found online. I had reached out to you directly with more information at the time of your original posting.
s.sobika  (posted 2018-03-15 08:31:17.77)
Hi, I have an ND530B filter and I would like to know if this filter preserve the polarization effect ?
llamb  (posted 2018-03-19 10:20:17.0)
Hello, thank you for contacting Thorlabs. While we do not have any specific polarization test data on this, the metal Inconel coating will likely introduce some polarization effects on your incident beam. It's not designed to be polarization-maintaining, so a small change in polarization is to be expected.
markus.augustin  (posted 2017-09-05 07:59:52.853)
Hi, I'm also interested in the tolerance of the ND05b and ND20b (or ND505b and ND520b). Can you please provide typical variation on the OD over range 400 - 1000 nm? Markus
tfrisch  (posted 2017-09-15 11:23:30.0)
Hello, thank you for contacting Thorlabs. The tolerance for OD is ±5% at the design wavelength of 633nm. I will reach out to you about typical data, but unfortunately, we do not have any statistical analysis on historical variations. We are able to offer individualized testing at other wavelengths, however.
cpepe  (posted 2017-03-06 09:17:17.513)
Hi, I have an ND10B filter which I can see is a bit dirty. I read that you recommend only to clean it with air but this didnt work. I therefore wanted to hear if you have any other recomendations or will eg methanol just make it worse?
tfrisch  (posted 2017-03-13 05:06:43.0)
Hello, thank you for contacting Thorlabs. Unfortunately, I would not recommend cleaning with any solvents as unprotected coatings are easily damaged by contact. I will reach out to you directly.
david.chadwick  (posted 2016-11-30 14:08:53.617)
I'm sure it's in there somewhere - Is there a maximum / minimum tolerance for the ND 3.0 value across the spectral band ? Thanks, Dave
tfrisch  (posted 2016-12-05 09:37:34.0)
Hi Dave, thank you for contacting Thorlabs. The tolerance we use for inspection is ±5% of the OD at the design wavelength (633nm in this case). I will contact you directly with typical data on the OD over the operating range.
pmartel  (posted 2015-04-14 08:02:20.793)
just purchased ND10B and similar filters. is there a particular face of the filter the laser should strike, or wors good either way? thanks for your input
besembeson  (posted 2015-04-21 06:08:04.0)
Response from Bweh at Thorlabs. The laser input should be to the face with the metal (inconel) coating.
user  (posted 2013-10-29 16:33:50.13)
Do you have data for the transmission for s- and p-polarized light?
tcohen  (posted 2013-10-29 13:14:00.0)
Response from Tim at Thorlabs: Thanks for your comment. These were measured at 0deg AOI for transmission, but if you’d like to see S&P data with some angle of incidence, we can provide further data. I don’t see that you left any contact info, so please let us know if you’d like to go over this further at Techsupport@thorlabs.com.
info  (posted 2013-08-05 13:25:29.13)
Welche absolute Genauigkeit hat der Filter ND20B bei 850 nm? Aus dem Diagramm läßt sich 1,1% ablesen, aber wie gut stimmen diese? Kunden NR 346016
jlow  (posted 2013-08-07 15:04:00.0)
Response from Jeremy at Thorlabs: The data on the graph is typical at that range and should be used as a guideline value. We could provide the filter specifically tested at 850nm if needed. We will get in contact with you to discuss about this.
tcohen  (posted 2013-02-21 14:55:00.0)
Response from Tim at Thorlabs to Ryan: Thank you for contacting us. We have reflectivity data past 1100nm on the “Graphs” tab and I will contact you directly to provide typical plots on %T extended past 1100nm.
tcohen  (posted 2012-05-22 11:55:00.0)
Response from Tim at Thorlabs: Thank you for your interest in our Reflective ND Filters. We are able to quote many custom optics and I will contact you directly to get more information so that we may provide pricing and lead time.
yu.zhang  (posted 2012-05-21 02:34:51.0)
N-BK7 Reflective Neutral Density Filters We are interested in this product. But we need the size to be 180 mm x 180 mm. Can thorlab customize for us? What will be the piece price (10 pieces for example)? Thanks!

Ø1/2" Unmounted Reflective ND Filters

Click on More Info Icon for a plot and downloadable data. The black dashed line indicates the designated optical density.


Item # Optical Densitya
(Transmission)
Transmission
Data
ND501B 0.1 (79%) info
ND502B 0.2 (63%) info
ND503B 0.3 (50%) info
ND504B 0.4 (40%) info
ND505B 0.5 (32%) info
ND506B 0.6 (25%) info
  • At 633 nm
Item # Optical Densitya
(Transmission)
Transmission
Data
ND510B 1.0 (10%) info
ND513B 1.3 (5%) info
ND520B 2.0 (1%) info
ND530B 3.0 (0.1%) info
ND540B 4.0 (0.01%) info
  • At 633 nm
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
ND501B Support Documentation
ND501BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.1
$29.69
Today
ND502B Support Documentation
ND502BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.2
$29.69
Today
ND503B Support Documentation
ND503BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.3
$29.69
Today
ND504B Support Documentation
ND504BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.4
$29.69
Today
ND505B Support Documentation
ND505BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.5
$29.69
Today
ND506B Support Documentation
ND506BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.6
$29.69
Today
ND507B Support Documentation
ND507BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.7
$29.69
Today
ND508B Support Documentation
ND508BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 0.8
$29.69
Today
ND509B Support Documentation
ND509B Unmounted Reflective Ø1/2" ND Filter, Optical Density: 0.9
$29.69
Today
ND510B Support Documentation
ND510BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 1.0
$29.69
Today
ND513B Support Documentation
ND513BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 1.3
$29.69
Today
ND515B Support Documentation
ND515BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 1.5
$35.82
Today
ND520B Support Documentation
ND520BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 2.0
$35.82
Today
ND530B Support Documentation
ND530BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 3.0
$35.82
Today
ND540B Support Documentation
ND540BUnmounted Reflective Ø1/2" ND Filter, Optical Density: 4.0
$35.82
Today

Ø25 mm Unmounted Reflective ND Filters

Click on More Info Icon for a plot and downloadable data. The black dashed line indicates the designated optical density.


Item # Optical Densitya
(Transmission)
Transmission
Data
ND01B 0.1 (79%) info
ND02B 0.2 (63%) info
ND03B 0.3 (50%) info
ND04B 0.4 (40%) info
ND05B 0.5 (32%) info
ND06B 0.6 (25%) info
  • At 633 nm
Item # Optical Densitya
(Transmission)
Transmission
Data
ND10B 1.0 (10%) info
ND13B 1.3 (5%) info
ND20B 2.0 (1%) info
ND30B 3.0 (0.1%) info
ND40B 4.0 (0.01%) info
  • At 633 nm
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
ND01B Support Documentation
ND01BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.1
$52.42
3 weeks
ND02B Support Documentation
ND02BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.2
$52.42
Today
ND03B Support Documentation
ND03BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.3
$52.42
Today
ND04B Support Documentation
ND04BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.4
$52.42
Today
ND05B Support Documentation
ND05BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.5
$52.42
Today
ND06B Support Documentation
ND06BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.6
$52.42
Today
ND07B Support Documentation
ND07BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.7
$52.42
Lead Time
ND08B Support Documentation
ND08BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.8
$52.42
Today
ND09B Support Documentation
ND09BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 0.9
$52.42
Lead Time
ND10B Support Documentation
ND10BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 1.0
$52.42
Today
ND13B Support Documentation
ND13BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 1.3
$58.23
Today
ND15B Support Documentation
ND15BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 1.5
$64.34
Today
ND20B Support Documentation
ND20BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 2.0
$64.34
Today
ND30B Support Documentation
ND30BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 3.0
$64.34
Today
ND40B Support Documentation
ND40BUnmounted Reflective Ø25 mm ND Filter, Optical Density: 4.0
$64.34
Today

Ø50 mm Unmounted Reflective ND Filters

Click on More Info Icon for a plot and downloadable data. The black dashed line indicates the designated optical density.


Item # Optical Densitya
(Transmission)
Transmission
Data
ND2R01B 0.1 (79%) info
ND2R02B 0.2 (63%) info
ND2R03B 0.3 (50%) info
ND2R04B 0.4 (40%) info
ND2R05B 0.5 (32%) info
ND2R06B 0.6 (25%) info
  • At 633 nm
Item # Optical Densitya
(Transmission)
Transmission
Data
ND2R10B 1.0 (10%) info
ND2R13B 1.3 (5%) info
ND2R20B 2.0 (1%) info
ND2R30B 3.0 (0.1%) info
ND2R40B 4.0 (0.01%) info
  • At 633 nm
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
ND2R01B Support Documentation
ND2R01BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 0.1
$73.37
Today
ND2R02B Support Documentation
ND2R02BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 0.2
$73.37
Today
ND2R03B Support Documentation
ND2R03BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 0.3
$73.37
Today
ND2R04B Support Documentation
ND2R04BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 0.4
$73.37
Today
ND2R05B Support Documentation
ND2R05BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 0.5
$73.37
Today
ND2R06B Support Documentation
ND2R06BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 0.6
$73.37
Today
ND2R07B Support Documentation
ND2R07BUnmounted Reflective Ø50 mm ND Filter, Optical Density: 0.7
$73.37
Today
ND2R08B Support Documentation
ND2R08BUnmounted Reflective Ø50 mm ND Filter, Optical Density: 0.8
$73.37
Today
ND2R09B Support Documentation
ND2R09BUnmounted Reflective Ø50 mm ND Filter, Optical Density: 0.9
$73.37
Today
ND2R10B Support Documentation
ND2R10BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 1.0
$73.37
Today
ND2R13B Support Documentation
ND2R13BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 1.3
$81.53
Today
ND2R15B Support Documentation
ND2R15BUnmounted Reflective Ø50 mm ND Filter, Optical Density: 1.5
$90.09
Today
ND2R20B Support Documentation
ND2R20BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 2.0
$90.09
Today
ND2R30B Support Documentation
ND2R30BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 3.0
$90.09
Today
ND2R40B Support Documentation
ND2R40BCustomer Inspired! Unmounted Reflective Ø50 mm ND Filter, Optical Density: 4.0
$90.09
Today

Unmounted 50 mm x 50 mm Reflective ND Filters

Click on More Info Icon for a plot and downloadable data. The black dashed line indicates the designated optical density.


Item # Optical Densitya
(Transmission)
Transmission
Data
ND201B 0.1 (79%) info
ND202B 0.2 (63%) info
ND203B 0.3 (50%) info
ND204B 0.4 (40%) info
ND205B 0.5 (32%) info
ND206B 0.6 (25%) info
  • At 633 nm
Item # Optical Densitya
(Transmission)
Transmission
Data
ND210B 1.0 (10%) info
ND213B 1.3 (5%) info
ND220B 2.0 (1%) info
ND230B 3.0 (0.1%) info
ND240B 4.0 (0.01%) info
  • At 633 nm
Based on your currency / country selection, your order will ship from Newton, New Jersey  
+1 Qty Docs Part Number - Universal Price Available
ND201B Support Documentation
ND201BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.1
$73.37
Today
ND202B Support Documentation
ND202BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.2
$73.37
Today
ND203B Support Documentation
ND203BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.3
$73.37
Today
ND204B Support Documentation
ND204BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.4
$73.37
Today
ND205B Support Documentation
ND205BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.5
$73.37
Today
ND206B Support Documentation
ND206BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.6
$73.37
Today
ND207B Support Documentation
ND207BUnmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.7
$73.37
Today
ND208B Support Documentation
ND208BUnmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.8
$73.37
Today
ND209B Support Documentation
ND209BUnmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 0.9
$73.37
Today
ND210B Support Documentation
ND210BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 1.0
$73.37
Today
ND213B Support Documentation
ND213BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 1.3
$81.53
Today
ND215B Support Documentation
ND215BUnmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 1.5
$90.09
Today
ND220B Support Documentation
ND220BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 2.0
$90.09
Today
ND230B Support Documentation
ND230BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 3.0
$90.09
Today
ND240B Support Documentation
ND240BCustomer Inspired! Unmounted Reflective 50 mm x 50 mm ND Filter, Optical Density: 4.0
$90.09
Today